Dynamic insulation¶
A building-envelope system that deliberately draws ventilation air through porous insulation so recovered conductive heat prewarms incoming air and makes effective heat transfer depend on airflow.
Core Idea¶
Dynamic insulation couples ventilation and envelope heat transfer by passing incoming air through insulation in the direction opposing conductive heat loss.[n1] Cool air absorbs heat from insulation fibers as it travels inward, recovering part of the outward conductive flux and supplying tempered ventilation air. The abstraction is therefore identified by a declared carrier, a transformation or constraint over that carrier, and an invariant that tells an analyst whether the named structure is genuinely present.
The load-bearing residual is not the broad topic of building science. It is airflow-dependent envelope conductance and integrated ventilation heat recovery. That residual remains recognizable when examples, notation, scale, or implementation change, but it disappears if the carrier is mistyped, the condition that airflow is intentional, distributed through the insulation and controlled so thermal, moisture, contaminant and pressure assumptions remain valid fails, a neighboring object is substituted, or notation and topical resemblance replace the constitutive test. This gives the entry an operational identity rather than merely a historical label.
A useful analysis keeps three layers separate. The constitutive layer says what must be true: airflow is intentional, distributed through the insulation and controlled so thermal, moisture, contaminant and pressure assumptions remain valid. The evidential layer asks what observation or proof warrants the claim: type the carrier, state every parameter and convention in the definition, test that airflow is intentional, distributed through the insulation and controlled so thermal, moisture, contaminant and pressure assumptions remain valid, compare the nearest accepted identity, and report counterexamples, uncertainty, and limiting cases. The use layer asks what reasoning becomes available once the identity is established: recognizing and comparing instances of Dynamic insulation, deriving its domain-specific consequences, selecting valid models or methods, and preventing transfer beyond its assumptions. Conflating the layers is the most common source of scope inflation.
Structural Signature¶
- Carrier: a porous insulated wall or roof, controlled outside-to-inside airflow, temperature gradient, pressure difference, heat and mass transfer, ventilation demand, filters, moisture and envelope airtightness
- Inputs or antecedent state: the exact building science carrier, defining parameters and conventions, boundary conditions, source evidence, comparison cases, and any measurement or proof assumptions needed to evaluate Dynamic insulation
- Constitutive operation: Cool air absorbs heat from insulation fibers as it travels inward, recovering part of the outward conductive flux and supplying tempered ventilation air.
- Invariant: airflow is intentional, distributed through the insulation and controlled so thermal, moisture, contaminant and pressure assumptions remain valid
- Recognition test: type the carrier, state every parameter and convention in the definition, test that airflow is intentional, distributed through the insulation and controlled so thermal, moisture, contaminant and pressure assumptions remain valid, compare the nearest accepted identity, and report counterexamples, uncertainty, and limiting cases
- Output or consequence: recognizing and comparing instances of Dynamic insulation, deriving its domain-specific consequences, selecting valid models or methods, and preventing transfer beyond its assumptions
- Failure boundary: the carrier is mistyped, the condition that airflow is intentional, distributed through the insulation and controlled so thermal, moisture, contaminant and pressure assumptions remain valid fails, a neighboring object is substituted, or notation and topical resemblance replace the constitutive test
What It Is Not¶
- It is not the whole field of building science. The field contains many questions and methods that do not instantiate Dynamic insulation.
- It is not its most familiar example. Outdoor air drawn inward through a mineral-fiber wall warms before entering the room while lowering net transmission loss. exhibits the structure, but the example is evidence for the abstraction rather than its definition.
- It is not the neighboring catalog concept Breathing wall. A breathing wall generally emphasizes vapor or passive gas permeability; dynamic insulation uses controlled bulk airflow through insulation as part of ventilation and heat recovery.
- It is not a claim that every boundary case has one uncontested classification. a generalized or degenerate case may change existence, uniqueness, measurement, or naming conventions, so the exact definition of Dynamic insulation must control the decision
- It is not an unrestricted metaphor for any process that seems similar. Outside building science, the vocabulary and validity conditions do not transfer literally.
Scope of Application¶
Dynamic insulation belongs to building science and is useful where the analyst can specify a porous insulated wall or roof, controlled outside-to-inside airflow, temperature gradient, pressure difference, heat and mass transfer, ventilation demand, filters, moisture and envelope airtightness, then evaluate airflow is intentional, distributed through the insulation and controlled so thermal, moisture, contaminant and pressure assumptions remain valid. The scope is broad within that domain but bounded by the need for airflow is intentional, distributed through the insulation and controlled so thermal, moisture, contaminant and pressure assumptions remain valid. This is a conceptual building-system identity, not construction specifications; real designs require qualified engineers and applicable codes.[1]
- Definition and recognition. Determine whether a proposed instance satisfies the constitutive conditions rather than merely sharing terminology.
- Construction or evolution. Track how the exact building science carrier, defining parameters and conventions, boundary conditions, source evidence, comparison cases, and any measurement or proof assumptions needed to evaluate Dynamic insulation are converted, constrained, or organized by Cool air absorbs heat from insulation fibers as it travels inward, recovering part of the outward conductive flux and supplying tempered ventilation air..
- Comparison. Compare instances using carrier, parameters, convention, domain, scale, boundary conditions, evidence, exact versus approximate form, and limiting behavior, without treating convenience measures as the definition.
- Boundary analysis. Diagnose cases where a generalized or degenerate case may change existence, uniqueness, measurement, or naming conventions, so the exact definition of Dynamic insulation must control the decision and state which convention or theorem controls the decision.
- Downstream reasoning. Use the established identity to support recognizing and comparing instances of Dynamic insulation, deriving its domain-specific consequences, selecting valid models or methods, and preventing transfer beyond its assumptions while preserving the assumptions under which the inference is valid.
Clarity¶
The abstraction clarifies a crowded vocabulary by making airflow is intentional, distributed through the insulation and controlled so thermal, moisture, contaminant and pressure assumptions remain valid the center of the account. A claim should name the carrier, the governing operation or relation, the applicable assumptions, and the recognition test. A bare label is insufficient because the name Dynamic insulation can be used for a formal identity, an implementation, or a neighboring result unless carrier and convention are stated. The disciplined statement is: given the exact building science carrier, defining parameters and conventions, boundary conditions, source evidence, comparison cases, and any measurement or proof assumptions needed to evaluate Dynamic insulation, the structure counts as Dynamic insulation exactly when airflow is intentional, distributed through the insulation and controlled so thermal, moisture, contaminant and pressure assumptions remain valid.
This format also separates identity from measurement. Empirical, computational, or documentary proxies support recognition only under declared validity and uncertainty assumptions; formal cases require proof rather than measurement. Measurements can be noisy, implementations can approximate, and proofs can use equivalent characterizations; none of those facts licenses changing the object being measured. When reports disagree, first check scope and convention, then data or proof, and only then interpret the disagreement as substantive.
Manages Complexity¶
Without the abstraction, an analyst must reason directly over many local details: the carrier roles, admissibility assumptions, competing conventions, derived invariants, boundary cases, and proof or validation obligations specific to Dynamic insulation. Dynamic insulation compresses them into the roles in the structural signature. That compression permits comparison across instances without erasing the variables that determine validity. It also exposes which details may be varied safely and which are constitutive.
The compression has a price. A single label can hide canonical, generalized, restricted, approximate, computational, empirical, and historically variant formulations of Dynamic insulation. Good use therefore carries a small declaration of assumptions alongside the name. The abstraction manages complexity when it reduces the state space of the question while keeping the failure boundary visible; it mismanages complexity when the label substitutes for that boundary analysis.
Abstract Reasoning¶
- Identify the carrier. State what the elements, states, objects, or observations are: a porous insulated wall or roof, controlled outside-to-inside airflow, temperature gradient, pressure difference, heat and mass transfer, ventilation demand, filters, moisture and envelope airtightness. Reject examples whose alleged carrier belongs to a different problem.
- Lock the constitutive rule. Express airflow is intentional, distributed through the insulation and controlled so thermal, moisture, contaminant and pressure assumptions remain valid independently of one notation or implementation. This step prevents the canonical example from becoming the definition.
- Derive consequences. From airflow is intentional, distributed through the insulation and controlled so thermal, moisture, contaminant and pressure assumptions remain valid, infer recognizing and comparing instances of Dynamic insulation, deriving its domain-specific consequences, selecting valid models or methods, and preventing transfer beyond its assumptions. Record each assumption used so that a later change of setting does not silently preserve an invalid conclusion.
- Test adversarial cases. Examine a generalized or degenerate case may change existence, uniqueness, measurement, or naming conventions, so the exact definition of Dynamic insulation must control the decision and an object that resembles Dynamic insulation in purpose or vocabulary but does not satisfy its invariant is outside the class. A robust identity explains why the first is convention-sensitive and why the second is outside the class.
- Compare and refine. Use carrier, parameters, convention, domain, scale, boundary conditions, evidence, exact versus approximate form, and limiting behavior to compare legitimate instances, and refine the model when discrepancies reflect hidden variation rather than failure of the abstraction itself.
Knowledge Transfer¶
Knowledge transfers strongly among subfields of building science because they reuse a porous insulated wall or roof, controlled outside-to-inside airflow, temperature gradient, pressure difference, heat and mass transfer, ventilation demand, filters, moisture and envelope airtightness, Cool air absorbs heat from insulation fibers as it travels inward, recovering part of the outward conductive flux and supplying tempered ventilation air., and type the carrier, state every parameter and convention in the definition, test that airflow is intentional, distributed through the insulation and controlled so thermal, moisture, contaminant and pressure assumptions remain valid, compare the nearest accepted identity, and report counterexamples, uncertainty, and limiting cases. A theorem, diagnostic, or modeling warning can travel when those roles remain literal. For example, the distinction between constitutive identity and a convenient observable transfers from Outdoor air drawn inward through a mineral-fiber wall warms before entering the room while lowering net transmission loss. to Design accounts for condensation, fire, filtration, wind pressure and fan energy under qualified building-engineering review..[2]
Transfer outside the home domain is weaker. The skeletal pattern—type the carrier, apply the defining mechanism of Dynamic insulation, preserve its invariant, and derive only consequences licensed by the stated boundary—may suggest an analogy, but the domain-specific mechanisms, admissible evidence, and consequences do not come along automatically. The safe transfer procedure maps each role explicitly, checks the invariant again, and refuses the name when only a superficial resemblance remains.
Examples¶
Canonical¶
Outdoor air drawn inward through a mineral-fiber wall warms before entering the room while lowering net transmission loss. The example exposes the carrier and directly tests that airflow is intentional, distributed through the insulation and controlled so thermal, moisture, contaminant and pressure assumptions remain valid; changing incidental notation preserves the identity, while removing that condition destroys it. This example is canonical because every role can be inspected: the carrier is a porous insulated wall or roof, controlled outside-to-inside airflow, temperature gradient, pressure difference, heat and mass transfer, ventilation demand, filters, moisture and envelope airtightness; the operative rule is Cool air absorbs heat from insulation fibers as it travels inward, recovering part of the outward conductive flux and supplying tempered ventilation air.; the invariant is airflow is intentional, distributed through the insulation and controlled so thermal, moisture, contaminant and pressure assumptions remain valid; and the result supports recognizing and comparing instances of Dynamic insulation, deriving its domain-specific consequences, selecting valid models or methods, and preventing transfer beyond its assumptions.[n1] Changing incidental notation or scale leaves the structure intact, while removing airflow is intentional, distributed through the insulation and controlled so thermal, moisture, contaminant and pressure assumptions remain valid destroys the classification.
Mapped back: a porous insulated wall or roof, controlled outside-to-inside airflow, temperature gradient, pressure difference, heat and mass transfer, ventilation demand, filters, moisture and envelope airtightness → Cool air absorbs heat from insulation fibers as it travels inward, recovering part of the outward conductive flux and supplying tempered ventilation air. → airflow is intentional, distributed through the insulation and controlled so thermal, moisture, contaminant and pressure assumptions remain valid → recognizing and comparing instances of Dynamic insulation, deriving its domain-specific consequences, selecting valid models or methods, and preventing transfer beyond its assumptions
Applied / In Practice¶
Design accounts for condensation, fire, filtration, wind pressure and fan energy under qualified building-engineering review. The applied case qualifies only because the same invariant and boundary test remain literal under changed parameters or implementation. The applied case is not licensed merely by vocabulary. It qualifies because the same recognition test—type the carrier, state every parameter and convention in the definition, test that airflow is intentional, distributed through the insulation and controlled so thermal, moisture, contaminant and pressure assumptions remain valid, compare the nearest accepted identity, and report counterexamples, uncertainty, and limiting cases—can be run and because the same failure boundary—the carrier is mistyped, the condition that airflow is intentional, distributed through the insulation and controlled so thermal, moisture, contaminant and pressure assumptions remain valid fails, a neighboring object is substituted, or notation and topical resemblance replace the constitutive test—remains meaningful.[1] The case also shows why practical outputs should report assumptions, resolution, and uncertainty instead of a naked label.
Mapped back: declared instance → recognition test → boundary check → qualified use
Structural Tensions¶
- T1: Axiomatic identity vs. operational recognition. The defining conditions may be exact while empirical or computational recognition is approximate. Neither pole can be removed without changing the analytical task. Diagnostic: Can the reviewer state both the exact condition and the evidence used to infer it?
- T2: Local roles vs. global consequence. The mechanism is enacted through local relations, but the abstraction is usually valued for a global classification or prediction. Neither pole can be removed without changing the analytical task. Diagnostic: Does the claimed global result actually follow from the declared local conditions?
- T3: Ideal form vs. finite representation. Theory states a clean invariant while data structures, measurements, or proofs expose only finite representations. Neither pole can be removed without changing the analytical task. Diagnostic: Would increasing resolution converge toward the same classification?
- T4: Canonical convention vs. legitimate variants. A standard formulation supports communication, while variants may preserve the same core under changed assumptions. Neither pole can be removed without changing the analytical task. Diagnostic: Which role is invariant across variants, and which convention-specific conclusion changes?
- T5: Compression vs. hidden assumptions. The name compresses a complex argument but can conceal prerequisites. Neither pole can be removed without changing the analytical task. Diagnostic: Can each downstream inference be traced to an explicit assumption?
- T6: Autonomous residual vs. reduction to catalog neighbors. The candidate uses broader structures but adds an identity-bearing residual. Neither pole can be removed without changing the analytical task. Diagnostic: After subtracting the proposed parent and named neighbors, does the constitutive residual still support independent diagnostics?
Structural–Framed Character¶
The entry is structurally mixed but domain-framed. Its portable skeleton is type the carrier, apply the defining mechanism of Dynamic insulation, preserve its invariant, and derive only consequences licensed by the stated boundary. Its identity-bearing terms—Dynamic insulation, carrier, parameter, invariant, boundary, evidence, model, transformation, and application—derive their meaning from building science and cannot be replaced by generic systems language without losing the tests that distinguish valid from invalid instances.
This mixed character explains why the abstraction is reusable inside the domain yet does not meet the Prime bar. The structure organizes reasoning, but its claims still depend on domain-specific objects, evidence, and intervention semantics.
Structural Core vs. Domain Accent¶
The structural core consists of a carrier, Cool air absorbs heat from insulation fibers as it travels inward, recovering part of the outward conductive flux and supplying tempered ventilation air., a recognition invariant, and a consequence. That skeleton may resemble patterns elsewhere, especially type the carrier, apply the defining mechanism of Dynamic insulation, preserve its invariant, and derive only consequences licensed by the stated boundary. The domain accent is not decorative: Dynamic insulation, carrier, parameter, invariant, boundary, evidence, model, transformation, and application determine what counts as an admissible carrier, a valid transition, and successful evidence.
The abstraction therefore remains domain-specific. A cross-domain reuse that preserves only words such as 'balance,' 'cut,' 'sequence,' 'loss,' or 'simulation' is metaphor. Literal transfer requires the original role structure and diagnostics, which in this case remain anchored in building science.
Instantiates / Related Primes¶
The proposed strict upward parent is prime:feedback. Controlled airflow recovers otherwise lost heat and changes envelope performance; building-physics coupling supplies the residual. This is a proposal-only workspace relationship: the accepted Prime supplies a genuinely instantiated structural prerequisite or superclass, while Dynamic insulation adds domain-specific constraints.
The entry does not collapse into that parent because airflow-dependent envelope conductance and integrated ventilation heat recovery It also declines a nearby thematic catalog node: the neighbor does not literally subsume the constitutive identity of Dynamic insulation. This explicit assert-and-decline pattern keeps the proposed DAG narrow and prevents a merely thematic edge.
The prospective workspace queue contains one strict upward edge to prime:feedback. No live DAG mutation is authorized.
Relationships to Other Abstractions¶
Current abstraction Dynamic insulation Domain-specific
Parents (1) — more general patterns this builds on
-
Dynamic insulation is a kind of Feedback Prime
The proposed strict upward parent is
prime:feedback.Controlled airflow recovers otherwise lost heat and changes envelope performance; building-physics coupling supplies the residual. This is a proposal-only workspace relationship: the accepted Prime supplies a genuinely instantiated structural prerequisite or superclass, while Dynamic insulation adds domain-specific constraints. The entry does not collapse into that parent because airflow-dependent envelope conductance and integrated ventilation heat recovery It also declines a nearby thematic catalog node: the neighbor does not literally subsume the constitutive identity of Dynamic insulation. This explicit assert-and-decline pattern keeps the proposed DAG narrow and prevents a merely thematic edge. The prospective workspace queue contains one strict upward edge toprime:feedback. No live DAG mutation is authorized.
Hierarchy path (1) — routes to 1 parentless root
- Dynamic insulation → Feedback
Neighborhood in Abstraction Space¶
Dynamic insulation sits in a moderately populated region (52nd percentile for distinctiveness): it has near-neighbors but no dense thicket of look-alikes.
Family — Thermodynamics & Energy Systems (27 abstractions)
Nearest neighbors
- Chilled beam — 0.92
- Passive solar building design — 0.89
- Thermal energy network — 0.89
- Cooling center — 0.88
- Computer cooling — 0.88
Computed from structural-signature embeddings · 2026-09-08
Not to Be Confused With¶
- Breathing wall. A breathing wall generally emphasizes vapor or passive gas permeability; dynamic insulation uses controlled bulk airflow through insulation as part of ventilation and heat recovery.
- One canonical example. An instance demonstrates the structure but does not define the whole abstraction.
- Measurement or implementation of Dynamic insulation. A proxy or realization is evidence for the abstraction, not the abstraction itself.
- Generalized Dynamic insulation. An extension qualifies only when its changed axioms and retained invariant are stated.
Notes¶
[n1] Source cited in the frozen article, 'How Tight is Too Tight?'. ↩a ↩b
References¶
[1] It requires air permeable walls and/or roof/ceiling so that when the building is depressurised air can flow from outside to inside through the insulation in the wall or roof or ceiling (Figs 1 and 2). The following explanation of dynamic insulation will, for simplicity, be set in the context of temperate or cold climates where the main energy use is for heating rather than cooling the building. In hot climates it may have application in increasing the heat loss from the building. As air flows inwards through the insulation it picks up, via the insulation fibres, the heat that is being conducted to the outside. Dynamic insulation is thus able to achieve the dual function of reducing the heat loss through the walls and/or roof whilst at the same time supplying pre-warmed air to the indoor spaces. Dynamic insulation would appear, therefore, to overcome the major disadvantage of airtight envelopes which is that the quality of the indoor air will deteriorate unless there is natural or mechanical ventilation. However, dynamic insulation also requires mechanical ventilation with heat recovery (MVHR) in order to recover the heat in the exhaust air. For the air to be continually drawn through the walls and/or roof/ceiling, a fan is needed to hold the building at a pressure of 5 to 10 Pascals below the ambient pressure. The air that is being continuously drawn through the wall or roof needs to be continuously vented to outside. This represents a heat loss which must be recovered. An air-to-air heat exchanger (Fig 2) is the simplest way to do this. 'Annotation for Air Tight Timber Frame Construction' {| class="wikitable" |- ! Element!! Description !! |- | 1 || brick cladding |- | 2 || ventilated cavity |- | 3 || sheathing board with breathing membrane on exterior surface |- | 4 || insulation |- | 5 || plasterboard (vapour control layer optional) |} thumb|right|Fig 2 Dynamically insulated house viewed as a system 'Annotation for Air Permeable Wall Construction' {| class="wikitable" |- ! Element!! Description !! |- | 1 || brick cladding |- | 2 || ventilated cavity |- | 3 || sheathing board (air permeable) |- | 4 || insulation (air permeable) |- | 5 || air control layer |- | 6 || ventilated cavity |- | 7 || plasterboard |} == Science of dynamic insulation == All the main features of dynamic insulation can be understood by considering the ideal case of one-dimensional steady state heat conduction and air flow through a uniform sample of air permeable insulation. Equation ( ), which determines the temperature T at a distance × measured from the cold side of the insulation, is derived from the total net flow of conduction and convective heat across a small element of insulation being constant. }} where u air speed through the insulation (m/s) c a specific heat of air (J/kg K) ρ a density of air (kg/m 3 ) λ a thermal conductivity of the insulation(W/m K) For two- and three-dimensional geometries computational fluid dynamics (CFD) tools are required to solve simultaneously the fluid flow and heat transfer equations through porous media. The idealised 1D model of dynamic insulation provide a great deal of physical insight into the conductive and convective heat transfer processes which provides a means of testing the validity of the results of CFD calculations. Furthermore, just as simple 1D steady state heat flow is assumed in the calculation of the heat transmission coefficients (U-values) that are used in the design, approval and building energy performance rating of buildings so the simple 1D steady state model of dynamic insulation is adequate for designing and assessing the performance of a dynamically insulated building or element of the building. Insulations such as polyurethane (PUR) boards, which due to their micro-structure, are not air permeable are not suitable for dynamic insulation. Insulations such as rock wool, glass wool, sheep's wool, cellulose are all air permeable and so can be used in a dynamically insulated envelope. In equation ( ) the air speed through the insulation, u is taken as positive when the air flow is in the opposite direction to the conductive heat flow (contra-flux). Equation ( ) also applies to steady state heat flow in multi-layered walls. Equation ( ) has an analytical solution }} For the boundary conditions: T(x) = T o at × = 0 T(x) = T L at × = L where the parameter A, with dimensions of length, is defined by: }} The temperature profile as calculated using equation ( ) for air flowing through a slab of cellulose insulation 0.2 m thick in which one side is at a temperature of 20 °C and the other is at 0 °C is shown in Fig 3. The thermal conductivity of cellulose insulation was taken to be 0.04 W/m 2 K. thumb|left|alt=|Fig 3 Air flowing through insulation from cold side to warm side (contra flux) == Contra-flux == Fig 3 shows the typical behaviour of the temperature profile through dynamic insulation where the air flows in the opposite direction to the heat flux. As the air flow increases from zero, the temperature profile becomes increasingly more curved. On the cold side of the insulation (x/L = 0) the temperature gradient becomes increasingly horizontal. As the conduction heat flow is proportional to the temperature gradient, the slope of the temperature profile on the cold side is a direct indication of the conduction heat loss through a wall or roof. On the cold side of the insulation the temperature gradient is close zero which is the basis for the claim often made that dynamic insulation can achieve a U-value of zero W/m 2 K. On the warm side of the insulation the temperature gradient gets steeper with increasing air flow. This implies heat is flowing into the wall at a greater rate than for conventional insulation (air speed = 0 mm/s). For the case shown of air flowing through the insulation at 1mm/s the temperature gradient on the warm side of the insulation x/L = 1) is 621 °C/m which compares with only 100 °C/m for the conventional insulation. This implies that with an air flow of 1mm/s the inner surface is absorbing 6 times as much heat as that for conventional insulation. A consequence of this is that considerably more heat has to be put into the wall if there is air flowing through from outside. Specifically a space heating system six time larger than that for a conventionally insulated house would be needed . It is frequently stated that in dynamic insulation the outside air is being warmed up by heat that would be lost in any case. The implication being that the outside air is being warmed by "free" heat. The fact that the heat flow into the wall increases with air speed is evidenced by the decreasing temperature of the inner surface (Table 2 and Fig 4 below). A dynamically insulated house requires also an air-to-air heat exchanger as does an airtight house. The latter has the further advantage that if it is well insulated it will require only a minimal space heating system. The temperature gradient at point in dynamic insulation can be obtained by differentiating equation ( ) }} From this the temperature gradient on the cold side of the insulation (x = 0) is given by }} and the temperature gradient on the warm side of the insulation (x = L) is given by }} From the temperature gradient on the cold side of the insulation (equation ( )) a transmission heat loss or U-value for a dynamically insulated wall, U dyn can be calculated (Table 1) }} This definition of dynamic U-value would appear to be consistent with Wallenten's definition. The ratio of the dynamic U-value to the static U-value (u=0 m/s) is {U_{static}}=\frac {A\,L}{e^\left(AL \right)-1} | }} 'Table 1 Dynamic U-value' {| class="wikitable" |- ! Air speed u, (mm/s)!! Temp gradient at x/L=0 (°C/m) !! Conductive heat loss (W/m 2 ) !! U dyn (W/m 2 K) |- | 0 || 100 || 4 || 0.2 |- | 0.25 || 41.8 || 1.672 || 0.084 |- | 0.5 || 14.6 || 0.584 || 0.029 |- | 0.75 || 4.49 || 0.1796 || 0.009 |- | 1.0 || 1.26 || 0.0504 || 0.003 |} With this definition, the U-value of the dynamic wall decreases exponentially with increasing air speed. As stated above the conductive heat flow into the insulation on the warm side is very much greater than that leaving the cold side. In this case it is 6.21 X 4 / 0.0504 = 493 times for an air speed of 1 mm/s (Table 1). This imbalance in conductive heat flow is raising the temperature of the incoming air. This large heat flow into the wall has a further consequence. At the surface of a wall, floor or ceiling there is thermal resistance which takes account of the convective and radiant heat transfer at these surfaces. For a vertical internal surface this thermal resistance has a value of 0.13 m 2 K/W. In a dynamically insulated wall, as the conduction heat flow into the wall increases then so does the temperature drop across this internal thermal resistance increase. The wall surface temperature will become increasingly colder (Table 2). The temperature profiles through dynamic insulation taking into account the decrease in surface temperature with increasing air flow is shown in Fig 4. thumb|right|alt=|Fig 4 Air flowing through insulation from cold side to warm side (contra flux) 'Table 2 Temperature drop across air film thermal resistance' {| class="wikitable" |- ! Air speed u,(mm/s)!! Temperature drop across the air film (°C) |- | 0 || 0.52 |- | 0.25 || 1.02 |- | 0.5 || 1.69 |- | 0.75 || 2.44 |- | 1.0 || 3.23 |} As the operative temperature of a room is a combination of the air temperature and the mean temperature of all the surfaces in the room this implies that people will feel increasingly cooler as the air flow through the wall increases. Occupants may be tempted to turn up the room thermostat to compensate and thereby increasing the heat loss. == Pro-flux == thumb|right|alt=|Fig 5 Air flowing through insulation from warm side to cold side (pro-flux) thumb|right|alt=|Fig 6 Heat Transmission through Wall v Air Speed through the Insulation Fig 5 shows the typical behaviour of the dynamic insulation temperature profile when the air flows in the same direction to the conductive heat flow (pro-flux). As air at room temperature flows outwards with increasing speed the temperature profile becomes increasingly more curved. On the warm side of the insulation the temperature gradient becomes increasingly horizontal as the warm air prevents the insulation cooling down in the linear way that would occur with no air flow. The conductive heat loss into the wall is very much less than that for conventional insulation. This does not mean that the transmission heat loss for the insulation is very low. On the cold side of the insulation the temperature gradient gets steeper with increasing air outward flow. This is because the air, having now cooled, is no longer able to transfer heat to the insulation fibres. In pro-flux mode heat is flowing out of the wall at a greater rate than the case for conventional insulation. Warm moist air flowing out through the insulation and cooling rapidly increases the risk of condensation occurring within the insulation which will degrade the thermal performance of the wall and could, if prolonged, lead to mould growth and timber decay. How the heat flow (W/m 2 K) from the outer or cold surface of the insulation varies with air flow through the insulation is shown in Fig 6. When the air, which is also cold, flows inwards (air speed is positive) then the heat loss decreases from that of conventional insulation towards zero. However, when warm air flows outwards through the insulation (air speed is negative) then the heat losses increase dramatically. This is why in a conventionally insulated building it is desirable to make the envelope airtight. In a dynamically insulated wall it is necessary to ensure the air flow is inward at all points of the building under all wind speeds and directions. == Influence of the wind == In general when the wind blows on a building then the air pressure, P w varies all over the building surface (Fig 7). thumb|right|alt=|Fig 7 Wind Pressure Distribution around a Building (Liddament, 1986) }} where P o a reference pressure (Pa) C p wind pressure coefficient (dimensionless) Liddament, and CIBSE, provide approximate wind pressure coefficient data for low rise buildings (up to 3 storeys). For a square plan building on an exposed site with the wind blowing directly on to the face of the building the wind pressure coefficients are as shown in Fig 8. For a wind speed of 5.7 m/s at ridge height (taken as 8m) there is zero pressure difference across the side walls when the building is depressurised to -10 Pa. The insulation in the windward and leeward walls is behaving dynamically in the contra-flux mode with U-values of 0.0008 W/(m 2 K) and 0.1 W/(m 2 K) respectively. Since the building has a square footprint the average U-value for the walls is 0.1252 W/m 2 K. For other wind speeds and directions, the U-values will be different. For wind speeds greater than 5.7 m/s at ridge height then the side walls are in pro-flux mode with a U value dramatically increasing with wind speed (Fig 6) At wind speeds greater than 9.0 m/s at ridge height the lee-ward switches from contra-flux to pro-flux mode. The average U-value for the four walls is now 0.36 W/(m 2 K), which is significantly greater than the 0.2 W/(m 2 K) for an air-tight construction. These changes from contra-flux to pro-flux mode could be delayed by depressurising the building below -10 Pa. By locating this building in a particular geographical location then wind speed data for this site may be used to estimate the proportion of the year in which one or more of the walls will be operating in the risky and high heat loss pro-flux mode. From the Rayleigh distribution of wind speed at the site of the building, it is possible to estimate the number of hours in a year during which the wind speed at a height of 10.0 m exceeds 7.83 m/s (estimated from the wind speed of 5.7 m/s at ridge height of 8.0 m). This is the total time during an average year in which a building with dynamically insulated walls has significant heat losses. If, by way of example, the building in Fig 8 were located in Footdee, Aberdeen, the Ordnance Survey Land Ranger grid reference is NJ955065. Entering NJ9506 into the UK windspeed data base returns for this site an average annual wind speed of 5.8 m/s at a height of 10 m. The Rayleigh distribution for this mean wind speed indicates wind speeds in excess of 8 m/s are likely to occur for 2348 hours in the year or about 27% of the year. The wind pressure coefficients for the walls of the building vary also with wind direction which changes throughout the year. Nevertheless, the above calculations indicate that a square plan building of 2 storeys located in Footdee, Aberdeen could have one or more of the walls operating in the risky and high heat loss pro-flux mode for about a quarter of the year. A more robust way of introducing dynamic insulation to a building that avoids the pressure variation around the building envelope is to make use of the fact that in a ventilated roof space the pressure is relatively uniform over the ceiling (Fig 9 ). Thus a building with a dynamically insulated ceiling would offer a consistent performance independent of a varying wind speed and direction. thumb|left|alt=|Fig 8 Wind Pressure Coefficients for Low Rise Building on an Exposed Site(Liddament, 1986) thumb|right|alt=|Fig 9 Wind Pressure Distribution around Ventilated Roof.png(Liddament, 1986) == Air control layer == The maximum depressurisation for a dynamically insulated building is normally limited to 10 Pa in order to avoid doors slamming shut or difficulty in opening doors. Dalehaug also recommended that the pressure difference through the construction at the design minimum air flow (> 0.5 m 3 /m 2 h) should be about 5 Pa. The function of the air control layer (Fig 1) in a dynamically insulated wall or ceiling is provide sufficient resistance to the air flow to achieve the required pressure drop at the design air flow rate. The air control layer requires to have a suitable air permeability and this is the key to making dynamic insulation work. The permeability of a material to air flow, Φ, (m 2 /hPa) is defined as the volume of air that flows through a cube of material 1m X 1m X 1m in one hour }} where A area of material through which air flows (m 2 ) L thickness of material through which air flows (m) V' volume flow rate of air (m 3 /h) ΔP pressure difference along the length L of material (Pa) Equation ( ) is a simplified form of Darcy's Law. In building applications the air is at ambient pressure and temperature and small changes in the viscosity of air are not significant. Darcy's Law can be used to calculate the air permeability of a porous medium if the permeability of the medium (m 2 ) is known. The air permeability of some materials that could be used in dynamically insulated walls or ceiling are listed in Table 3. Air permeability data is crucial to the selection of the correct material for the air control layer. Further sources of air permeability data include ASHRAE and Kumaran. 'Table 3: Measured Air Permeability of Building Materials' {| class="wikitable" |- ! Material!! Density (kg/m 3 ) !!Permeability (m 2 /hPa)!! Component !! Permeance(m 3 /m 2 hPa)!! Pressure Drop 1 (Pa) |- | Plasterboard ||-||1.06x10-5 || 12 mm sheet || 8.81x10-4 || 1140 |- | Thermal block || 850 || 1.6x10-5 || 100 mm block || 1.6x10-4 || 526 |- | Fibreboard ||-|| 1.34x10-3 || 12 mm sheet || 0.116 || 8.6 |- | “Pumalite” || 870 || 0.036 || 100 mm block || 0.36 || 2.8 |- | Cellulose / wet blown || 47 || 0.283 || 200 mm || 1.50 || 0.67 |- | Cellulose / dry blown || 65 || 0.25 || 150 mm || 1.67 || 0.60 |- | Sheep's wool || 28 || 1.8 || 140 mm || 13.0 || 0.08 |} (1) Pressure drop calculated at flow rate of 1 m 3 /m 2 h == Design of a dynamic insulated building == The application of the theory of dynamic insulation is best explained by way of an example. Assume a house of 100 m 2 floor area with a dynamically insulated ceiling. Putting dynamic insulation in the ceiling effectively limits the house to a single storey. The first step is to decide on an appropriate air change rate for good air quality. As this air flow rate will be supplied through the dynamically insulated ceiling and a mechanical ventilation and heat recovery system (MVHR), energy loss is not a major concern so 1 air change per hour (ach) will be assumed. If the floor to ceiling height is 2.4 m this implies an air flow rate of 240 m 3 /h, part of which is supplied through the dynamically insulated ceiling and partly through the MVHR. Next the material for the air control layer is chosen to provide a suitable air flow rate at the chosen depressurisation, taken as 10 Pa in this case. (The air flow rate could be determined from the desired U-value at the depressurisation of 10 Pa.) From Table 4, fibreboard has an appropriate air permeability of 1.34×10 −3 (m 2 /hPa). For a 12mm thick sheet of fibreboard this gives, for the maximum pressure difference of 10 Pa, an air flow rate of 1.12 m 3 /h per m 2 of ceiling. This is equivalent to an air speed through the ceiling of 1.12 m/h or 0.31 mm/s. The 100 m 2 ceiling will thus provide 112 m 3 /h and therefore an air-to-air heat exchanger will provide the balance of 128 m 3 /h Dynamic insulation works best with a good thickness of insulation so taking 200 mm of cellulose insulation (k = 0.04 W/m °C) the dynamic U value for an air flow of 0.31 mm/s is calculated using equation ( ) above to be 0.066 W/m 2 °C. If a lower dynamic U-value is required then a material with lower air permeability than fibreboard would need to be selected for the air control layer, so that a higher air speed through the insulation at 10 Pa can be achieved. The final step would be to select an air-to-air heat exchanger that had a good heat recovery efficiency with a supply air flow rate of 128 m 3 /h and an extract air flow rate of 240 m 3 /h. See also * List of insulation material * Wind loads on buildings * Laminar flow * Porous medium References {{reflist| refs= Easley, S., 2007, How Tight is too Tight?, LBM Journal, Nov. www.LBMJournal.com. registry ↩a ↩b
[2] Wallenten, P., 1995, Analytical and Numerical Analysis of Dynamic Insulation, International, Building Performance Simulation Association, Fourth International Conference, 14 – 16 August, Madison, Wisconsin. registry ↩