ANSI B109.6 draft, section 7.4 Base Conditions¶
American Gas Association. (2026). ANSI B109.6 draft, section 7.4 Base Conditions.
Cited by¶
1 citation across 1 artifact.
Domain-specific¶
- Base Conditions
- In fluid measurement, base conditions are a declared reference temperature and absolute pressure to which a measured or metered volume is converted.
SupportedVerified against the work's full text
The draft standard defines base conditions as the base pressure (absolute) and temperature, 14.73 psi and 60°F, to which measured natural-gas volumes are corrected.
“1.4 BASE CONDITIONS. The standard or base conditions of pressure and temperature for the volumetric measurement of natural gas. As used in this standard 14.73 psi (101.56 kPa) and 60°F (15.6°C) are established as the base pressure and temperature respectively to which all volumes are commonly referred.”
- In fluid measurement, base conditions are a declared reference temperature and absolute pressure to which a measured or metered volume is converted.
Verification¶
Does it exist? Not checked yet. This entry carries no identifier to resolve. It was extracted from the citation as written in the article, normalized, and deduplicated against the rest of the registry.
Does it back the claim? Read against the text for 1 of 1 citation: 1 supported. Each verdict is shown under its citation below, with what in the work backs the sentence.
Support is checked per citation rather than per work — the same source can be cited soundly in one article and wrongly in another. Per-citation recording began recently, so a citation with no recorded check is a gap in the record rather than evidence it went unchecked.
See how references were verified.
Registry ID ref:facef389a0e0 · see in the full table